;-------------------------------------- ;---Rui Fonseca Vaz ;---Departamento de Eng. Electromecânica ;---Universidade da Beira Interior ;---Covilhã ;-------------------------------------- [FileInfo] FileName=TCA.EDS FileVersion=0 Filerevision=0 Description=EDS-File Teclado Central de Alarme CreationTime=10:30AM CreationDate=29-09-10 CreatedBy=RFV [DeviceInfo] VendorName=UBI VendorNumber=2214 ProductName= Teclado Central de Alarme ProductNumber=123 RevisionNumber=1 OrderCode=Security - 123 BaudRate_10=0 */ Número de Bits Transmissíveis /* BaudRate_20=0 BaudRate_50=1 BaudRate_125=0 BaudRate_250=0 BaudRate_500=0 BaudRate_800=0 BaudRate_1000=0 SimpleBootUpMaster=0 SimpleBootUpSlave=1 ExtendedBootUpMaster=0 ExtendedBootUpSlave=0 Granularity=8 */ A maior parte suporta apenas 8 /* [StandardDataTypes] 0x0001=0 0x0002=0 0x0003=0 0x0004=0 0x0005=1 0x0006=1 0x0007=1 0x0008=0 0x0009=1 0x000A=1 0x000B=0 0x000C=1 0x000D=1 0x000E=1 0x000F=0 0x0020=1 0x0021=1 [DummyUsage] Dummy0001=0 Dummy0002=0 Dummy0003=0 Dummy0004=0 Dummy0005=0 Dummy0006=0 Dummy0007=0 [MandatoryObjects] SupportedObjects=2 1=0x1000 2=0x1001 [1000] Subnumber=0 ParameterName=device type ObjectType=0x07 DataType=0x0007 AcessType=ro LowLimit= HighLimit= DefaultValue=0x00030000 PDOMapping=0 [1001] SubNumber=0 Parametername=error register ObjectType=0x07 DataType=0x0005 AcessType=ro LowLimit= HighLimit= DefaultValue=2 PDOMapping=1 [OptionalObjects] SupportedObjects=13 1=0x1002 2=0x1004 3=0x1005 4=0x1006 5=0x1007 6=0x1008 7=0x1009 8=0x100A 9=0x100F 10=0x1010 11=1x1011 12=0x1400 13=0x1800 [1000] Subnumber=0 ParameterName=device type ObjectType=7 dataType=0x0007 DefaultValue=0x30000 AcessType=ro PDOMapping=0 [1001] SubNumber=0 ParameterNumber=error register ObjectType=0x07 DataType=0x0005 AcessType=ro LowLimit= HighLimit= DefaultValue= PDOMapping=1 [1002] SubNumber=0 ParameterNumber=manufactured status register ObjectType=0x07 DataType=0x0007 AcessType=ro LowLimit= HighLimit= DefaultValue= PDOMapping=0 [1004] SubNumber=2 ParameterName=number of PDOs supported [1004sub0] ParameterName=number of PDOs supported ObjectType=0x0008 DataType=0x07 AcessType=ro DefaultValue=0x10001 PDOMapping=0 [1004sub1] ParameterName=number of synchronous PDOs ObjectType=0x0008 DataType=0x07 AcessType=ro DefaultValue=0x00000 PDOMapping=0 [1004sub2] ParameterName=number of assynchronous PDOs ObjectType=0x0008 DataType=0x07 AcessType=ro DefaultValue=0x10001 PDOMapping=0 [1005] SubNumber=0 ParameterNumber=communication cycle period ObjectType=0x07 DataType=0x0007 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1006] SubNumber=0 ParameterName=communication cycle period ObjectType=0x07 DataType=0x0007 AcessType=rw LowLimit= HighLimit= DefaultValue00x00 PDOMapping=0 [1007] SubNumber=0 ParameterNumber=synchronous window length ObjectType=0x07 DataType=0x0007 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1008] SubNumber=0 ParameterNumber=manufactured device name ObjectType=0x07 DataType=0x0009 AcessType=const LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1009] SubNumber=0 ParameterNumber=manufactured hardware version ObjectType=0x07 DataType=0x0009 AcessType=const LowLimit= HighLimit= DefaultValue=0 PDOMapping=0 [100A] SubNumber=0 ParameterNumber=manufactured software version ObjectType=0x07 DataType=0x0009 AcessType=const LowLimit= HighLimit= DefaultValue=0 PDOMapping=0 [100F] SubNumber=0 ParameterNumber=number of SDO´s supported ObjectType=0x07 DataType=0x07 AcessType=ro LowLimit= HighLimit= DefaultValue=0x00000001 PDOMapping=0 [1010] SubNumber=4 ParameterName=store parameters [1010sub0] ParameterName=largest supported Subindex ObjectType=0x0008 DataType=0x05 AcessType=ro LowLimit= HighLimit= DefaultValue=0x04 PDOMapping=0 [1010sub1] ParameterName=save all parameters ObjectType=0x0008 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1010sub2] ParameterName=save communication parameters ObjectType=0x0008 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1010sub3] ParameterName=save aplication parameters ObjectType=0x0008 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1010sub4] ParameterName=save manufactured defined parameters ObjectType=0x0008 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1011] SubNumber=4 Parametername=restore default parameters [1011sub0] ParameterName=largest supported Subindex ObjectType=0x0008 DataType=0x05 AcessType=ro LowLimit= HighLimit= DefaultValue=0x04 PDOMapping=0 [1011sub1] ParameterName=restore all default parameters ObjectType=0x0008 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1011sub2] ParameterName=restore communication default parameters ObjectType=0x0008 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1011sub3] ParameterName=restore application default parameters ObjectType=0x0008 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1011sub4] ParameterName=restore manufactured define default ObjectType=0x0008 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0x00 PDOMapping=0 [1400] SubNumber=3 ParameterName=RPDO 1 Communication Parameter [1400sub0] ParameterName=number of supported entries ObjectType=0x0009 DataType=0x05 AcessType=ro LowLimit= HighLimit= DefaultValue=2 PDOMapping=0 [1400sub1] ParameterName=COB-ID used by PDO ObjectType=0x0009 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0 PDOMapping=0 [1400sub2] ParameterName=transmission type ObjectType=0x0009 DataType=0x05 AcessType=rw LowLimit= HighLimit= DefaultValue=0xfe PDOMapping=0 [1800] Subnumber=2 ParameterName=TPDO 1 Communication Parameter [1800sub0] ParameterName=number of supported entries ObjectType=0x0009 DataType=0x05 AcessType=ro LowLimit= HighLimit= DefaultValue=2 PDOMapping=0 [1800sub1] ParameterName=COB-ID used by PDO ObjectType=0x0009 DataType=0x07 AcessType=rw LowLimit= HighLimit= DefaultValue=0 PDOMapping=0 [1800sub2] ParameterName=transmission type ObjectType=0x0009 DataType=0x05 AcessType=rw LowLimit= HighLimit= DefaultValue=0xfe PDOMapping=0 [ManufacturerObjects] SupportedObjects=2 1=0x201E 2=0x201F [201E] ParameterName=Feedback do modo de funcionamento ObjectType=0x0007 DataType=0x05 acessType=rw LowLimit= HighLimit= DefaultValue=0x02 PDOMapping=1 [201F] ParameterName=Feedback da zona de funcionamento ObjectType=0x0007 DataType=0x05 acessType=rw LowLimit= HighLimit= DefaultValue=0x02 PDOMapping=1