Publication
Best Practices on HVAC Design to Minimize the Risk of COVID-19 Infection within Indoor Environments
dc.contributor.author | Santos, Alexandre Fernandes | |
dc.contributor.author | Gaspar, Pedro Dinis | |
dc.contributor.author | Hamandosh, Aseel | |
dc.contributor.author | Aguiar, Eliandro | |
dc.contributor.author | Filho, António Carlos Guerra | |
dc.contributor.author | Souza, Heraldo | |
dc.date.accessioned | 2022-03-29T15:28:19Z | |
dc.date.available | 2022-03-29T15:28:19Z | |
dc.date.issued | 2020-06-20 | |
dc.description.abstract | The spread of Coronavirus is causing in the society all around the world a considerable degree of fear, worry and concern and particularly among healthcare workers that are at increased risk for infection. This paper gathers the strategy/guidelines to reduce the contamination in Intensive care unit (ICU) and in all the hospital environment. The ASHRAE and REHVA guidelines applied the UV-C Lamps, Pressure control filtration, Restroom actions and Humidity control to reduce the coronavirus disease (Covid-19) in ICU. The role of infection control in the design of hospitals is increasing every day. This paper highlights the role of heating, ventilating and air-conditioning minimizing the risk of infection from airborne transmission within the built environment through the application of best practices. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.doi | 10.1590/1678-4324-2020200335 | pt_PT |
dc.identifier.issn | 1678-4324 | |
dc.identifier.uri | http://hdl.handle.net/10400.6/12132 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.relation.publisherversion | https://www.scielo.br/j/babt/a/xPWBJ5hCnKQWJFF7PF6JrXL/?lang=en | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ | pt_PT |
dc.subject | COVID 19 | pt_PT |
dc.subject | Pandemic | pt_PT |
dc.subject | Contamination | pt_PT |
dc.subject | Strategies | pt_PT |
dc.subject | Guidelines | pt_PT |
dc.subject | Best Practices | pt_PT |
dc.title | Best Practices on HVAC Design to Minimize the Risk of COVID-19 Infection within Indoor Environments | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.title | Brazilian Archives of Biology and Technology | pt_PT |
oaire.citation.volume | 63 | pt_PT |
person.familyName | Fernandes Santos | |
person.familyName | Gaspar | |
person.familyName | Hamandosh | |
person.familyName | Aguiar | |
person.familyName | Guerra Filho | |
person.familyName | Souza | |
person.givenName | Alexandre | |
person.givenName | Pedro Dinis | |
person.givenName | Aseel | |
person.givenName | Eliandro | |
person.givenName | Antonio Carlos | |
person.givenName | Heraldo | |
person.identifier.ciencia-id | 6111-9F05-2916 | |
person.identifier.orcid | 0000-0001-5306-6968 | |
person.identifier.orcid | 0000-0003-1691-1709 | |
person.identifier.orcid | 0000-0002-2658-8039 | |
person.identifier.orcid | 0000-0001-9994-7736 | |
person.identifier.orcid | 0000-0003-3631-1348 | |
person.identifier.orcid | 0000-0002-8471-7804 | |
person.identifier.rid | N-3016-2013 | |
person.identifier.scopus-author-id | 57419570900 | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | dc73b2e8-4a09-433a-8015-cb876d3d2da0 | |
relation.isAuthorOfPublication | b69e2ba0-43af-4cf7-873e-090fd9fc6c94 | |
relation.isAuthorOfPublication | 75ffff20-463f-4452-a70d-9df000201ae0 | |
relation.isAuthorOfPublication | 2ab92823-9428-4bd5-a5e2-c137a33b58cd | |
relation.isAuthorOfPublication | aebe0378-69fc-4b2b-a9ef-8e95a24ee856 | |
relation.isAuthorOfPublication | 7daa9e1e-c336-42c1-ae21-d3161ed1c7bc | |
relation.isAuthorOfPublication.latestForDiscovery | 2ab92823-9428-4bd5-a5e2-c137a33b58cd |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- IJI0023-Best Practices on HVAC Design to Minimize the Risk of COVID-19 Infection within Indoor Environments.pdf
- Size:
- 443.15 KB
- Format:
- Adobe Portable Document Format