Repository logo
 
Publication

Validity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strength

dc.contributor.authorSousa, António Carlos
dc.contributor.authorMarques, Diogo Luís
dc.contributor.authorCalado, António Manuel
dc.contributor.authorPacheco, Carlos
dc.contributor.authorMarinho, Daniel
dc.contributor.authorMarques, Mário Cardoso
dc.contributor.authorTravassos, Bruno
dc.date.accessioned2022-11-21T09:51:38Z
dc.date.available2022-11-21T09:51:38Z
dc.date.issued2022-04-01
dc.description.abstractWe analyzed the Smart Groin Trainer device's validity and reliability to measure the isometric hip adduction strength during the adductor squeeze strength test. Fifteen professional soccer players (25.33±4.06 years) and fifteen university students (21.60±1.76 years) participated in this study. All participants performed the squeeze strength test using two portable dynamometers: Smart Groin Trainer and Globus Ergometer. Three maximal isometric hip adduction contractions lasting 5s, interspersed by 3min rest intervals, were performed. Reliability was analyzed with intraclass correlation coefficients, standard error of measurements, and minimal detectable change. The absolute percent error and inter-device accuracy were also analyzed. Correlation analysis assessed the inter-device concurrent validity. The results found no significant differences (p>0.05) between devices in the squeeze strength test values in soccer players and university students. Inter-device comparisons revealed excellent levels of reliability and accuracy in soccer players. Concurrent validity measures revealed strong inter-device relationships in soccer players (r=0.89) and very strong relationships in university students (r=0.99). Intra-device analysis using the Smart Groin Trainer showed excellent relative and absolute reliability in tested soccer players. Our data demonstrated excellent levels of agreement between both dynamometers during the squeeze strength test, suggesting the Smart Groin Trainer as a valid, reliable, and accurate device to measure isometric hip adduction strength.pt_PT
dc.description.sponsorshipThis research was funded under the NANOSTIMA project Macro-to-Nano Human Sensing: Towards Integrated Multimodal Health Monitoring and Analytics of operation NORTE-01-0145-FEDER-000016, co-financed by the European Regional Development Fund (ERDF) through the NORTE 2020 (North Regional Operational Program 2014/2020) and supported by the Portuguese Foundation for Science and Technology, I.P., grant number UID04045/2020, Portugal. Diogo Luís Marques is funded by the Portuguese Foundation for Science and Technology, grant number SFRH/BD/147608/2019.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.2478/hukin-2022-0029pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.6/12394
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.relationOs Efeitos Agudos e Crónicos do Treino Concorrente no Desempenho Físico e Cognitivo do Idoso: A Importância do Volume e da Velocidade de Execução
dc.relationResearch Center in Sports Sciences, Health and Human Development
dc.subjectPortable dynamometerpt_PT
dc.subjectGroinpt_PT
dc.titleValidity and Reliability of the Smart Groin Trainer for Measuring Hip Adduction Strengthpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.awardTitleOs Efeitos Agudos e Crónicos do Treino Concorrente no Desempenho Físico e Cognitivo do Idoso: A Importância do Volume e da Velocidade de Execução
oaire.awardTitleResearch Center in Sports Sciences, Health and Human Development
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/POR_NORTE/SFRH%2FBD%2F147608%2F2019/PT
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/UIDB%2F04045%2F2020/PT
oaire.citation.endPage59pt_PT
oaire.citation.issue1pt_PT
oaire.citation.startPage51pt_PT
oaire.citation.titleJournal of Human Kineticspt_PT
oaire.citation.volume82pt_PT
oaire.fundingStreamPOR_NORTE
oaire.fundingStream6817 - DCRRNI ID
person.familyNameSousa
person.familyNameMarques
person.familyNameMarinho
person.familyNameMARQUES
person.familyNameTravassos
person.givenNameAntónio Carlos
person.givenNameDiogo
person.givenNameDaniel
person.givenNameMÁRIO
person.givenNameBruno
person.identifier.ciencia-id0D10-833C-31A7
person.identifier.ciencia-idDF1F-7CAA-7866
person.identifier.ciencia-id471B-F3CC-479A
person.identifier.ciencia-idEA13-7532-0A6D
person.identifier.ciencia-id5F1A-5DFD-8FBE
person.identifier.orcid0000-0002-9762-7867
person.identifier.orcid0000-0002-6653-0616
person.identifier.orcid0000-0003-2351-3047
person.identifier.orcid0000-0002-5812-1580
person.identifier.orcid0000-0002-2165-2687
person.identifier.scopus-author-id15022568500
person.identifier.scopus-author-id24773599000
person.identifier.scopus-author-id36490697400
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.nameFundação para a Ciência e a Tecnologia
project.funder.nameFundação para a Ciência e a Tecnologia
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication87e7d532-ef9b-429e-812c-a2ab1ccff3b1
relation.isAuthorOfPublication4967e50f-2df3-4a96-9238-cfed2b4fb6bf
relation.isAuthorOfPublication1b7a1cda-cf15-4686-bb08-1ac47b66b314
relation.isAuthorOfPublicationb410e6a7-5e97-4946-9f86-260182107ffb
relation.isAuthorOfPublication44921471-78bc-4cb3-997f-920fdc726c8d
relation.isAuthorOfPublication.latestForDiscovery87e7d532-ef9b-429e-812c-a2ab1ccff3b1
relation.isProjectOfPublication444519cb-e82f-435b-97cd-fb3df33c84df
relation.isProjectOfPublication52e8061f-82ad-4adb-82d2-98a922cafc37
relation.isProjectOfPublication.latestForDiscovery52e8061f-82ad-4adb-82d2-98a922cafc37

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2022_Sousa_Validity and reliability of the smart groin trainer.pdf
Size:
421.37 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: