Experimental analysis of the thermal entrainment three dimensional effects in re-circulated air curtains

dc.contributor.authorGaspar, Pedro Dinis
dc.contributor.authorGonçalves, Luís Carlos Carrilho
dc.contributor.authorPitarma, Rui A.
dc.date.accessioned2019-10-21T09:40:43Z
dc.date.available2019-10-21T09:40:43Z
dc.date.issued2007-01
dc.description.abstractThe application of air curtains devices to HVAC&R systems have been developed in order to improve the thermal and mass separation between two contiguous spaces with differentiated air behaviours. The refrigeration equipments installed inside commercial spaces and open to the surroundings suffer alterations of their thermal behaviours and energy efficiency due to variations in magnitude and orientation of the air velocity. The location of the air conditioning system discharge grilles, the mass flows rates originated by pressure differences due to openings to the external environment and the air flow perturbation due to the circulation of the consumers nearby the opening of the display cases, among others, affect the re-circulated air curtain behaviour and the overall performance of the equipment.This study presents the experimental results obtained from tests carried out for the climatic class n.º 3 of EN 441 (Tamb = 25 ºC, φamb = 60%; vamb = 0,2 m/s) and the analysis of the threedimensional effects observed in the thermal interaction through the air curtains installed in open vertical refrigerated display cases. The obtained results are related to the air temperature, air relative humidity and air velocity measurements fields throughout the air curtain. From the analysis of the obtained results some comparable effects in the fields of the same properties for the display space of the exposition and conservation of food products and nearby the inlets/outlets of the air mass flow, can be sorted out. The evaluation of the ambient air velocity three-dimensional effects in the pattern of this type of turbulent air flow is obtained. Additionally, it is verified that the longitudinal airflow fluctuations and the length extremity effects of the display case have a considerable influence in the overall thermal performance of the equipment. The non-uniform distribution of the air temperature, relative humidity and velocity throughout the air curtain determines temperature differences in the linear dimension display space and inside the food products, affecting the correct behaviour of the display cases. Besides that, this study helps to show some of the fragilities of the numerical models bi-dimensional formulation.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationGaspar, Pedro & Carrilho, Francisco & Pitarma, Rui. (2007). Experimental Analysis of the Thermal Entrainment Three Dimensional Effects in Re-Circulated Air Curtains.pt_PT
dc.identifier.isbn978-952-99898-1-2
dc.identifier.urihttp://hdl.handle.net/10400.6/7305
dc.language.isoengpt_PT
dc.subjectRefrigeration equipmentspt_PT
dc.subjectRe-Circulated Air Curtainspt_PT
dc.titleExperimental analysis of the thermal entrainment three dimensional effects in re-circulated air curtainspt_PT
dc.typejournal article
dspace.entity.typePublication
person.familyNameGaspar
person.familyNamePitarma
person.givenNamePedro Dinis
person.givenNameRui António
person.identifier.ciencia-id6111-9F05-2916
person.identifier.ciencia-idA71F-60BB-8E5A
person.identifier.orcid0000-0003-1691-1709
person.identifier.orcid0000-0001-9486-0631
person.identifier.ridN-3016-2013
person.identifier.scopus-author-id57419570900
person.identifier.scopus-author-id6508229788
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationb69e2ba0-43af-4cf7-873e-090fd9fc6c94
relation.isAuthorOfPublicationb573965a-01d7-411d-9ace-83bc6dfaab38
relation.isAuthorOfPublication.latestForDiscoveryb573965a-01d7-411d-9ace-83bc6dfaab38

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Paper_RV_07_GasparCarrilhoPitarma.pdf
Size:
310.66 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: