- Ecoenergetic Comparison of HVAC Systems in Data CentersPublication . Santos, Alexandre F.; Gaspar, Pedro Dinis; Souza, Heraldo J. L. deThe topic of sustainability is of high importance today. Global efforts such as the Montreal Protocol (1987) and the Kigali Amendment (2016) are examples of joint work by countries to reduce environmental impacts and improve the level of the ozone layer, the choice of refrigerants and air conditioning systems, which is essential for this purpose. But what indicators are to be used to measure something so necessary? In this article, the types of air conditioning and GWP (Global Warming Potential) levels of equipment in the project phase were discussed, the issue of TEWI (Total Equivalent Warming Impact) that measures the direct and indirect environmental impacts of refrigeration equipment and air conditioning and a new methodology for the indicator was developed, the TEWI DC (DC is the direct application for Data Center), and using the formulas of this new adapted indicator it was demonstrated that the TEWI DC for Chicago (USA) was 2,784,102,640 kg CO2/10 years and Curitiba (Brazil) is 1,252,409,640 kg CO2/10 years. This difference in value corresponds to 222.30% higher annual emissions in Chicago than in Curitiba, showing that it is much more advantageous to install a Data Center in Curitiba than in Chicago in terms of environmental impact. The TEWI indicator provides a more holistic view, helping to combine energy and emissions into the same indicator.
- Evaluation of the Thermal Performance and Energy Efficiency of CRAC Equipment through Mathematical Modeling Using a New Index COP WEUEDPublication . Santos, Alexandre F.; Gaspar, Pedro Dinis; Souza, Heraldo J. L. deAs the world data traffic increasingly grows, the need for computer room air conditioning (CRAC)-type equipment grows proportionally. The air conditioning equipment is responsible for approximately 38% of the energy consumption of data centers. The energy efficiency of these pieces of equipment is compared according to the Energy Standard ASHRAE 90.1-2019, using the index Net Sensible Coefficient Of Performance (NetSCOP). This method benefits fixed-speed compressor equipment with a constant inlet temperature air-cooled condenser (35 C). A new method, COP WEUED (COP–world energy usage effectiveness design), is proposed based on the IPLV (integrated part load value) methodology. The IPLV is an index focused on partial thermal loads and outdoor temperature data variation for air intake in the condenser. It is based on the average temperatures of the USA’s 29 major cities. The new method is based on the 29 largest cities worldwide and with datacenter- specific indoor temperature conditions. For the same inverter compressor, efficiencies of 4.03 and 4.92 kW/kW were obtained, using ASHRAE 90.1-2019 and the proposed method, respectively. This difference of almost 20% between methods is justified because, during less than 5% of the annual hours, the inlet air temperature in the condenser is close to the NetSCOP indication.