CFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinets

dc.contributor.authorGaspar, Pedro Dinis
dc.contributor.authorGonçalves, Luís Carlos Carrilho
dc.contributor.authorGe, Xiao
dc.date.accessioned2019-11-19T09:45:04Z
dc.date.available2019-11-19T09:45:04Z
dc.date.issued2010-06
dc.description.abstractThe thermal behaviour of open refrigerated display cabinets depends of ambient air condition variations such as air temperature, relative humidity and velocity magnitude and orientation. The location of air conditioning system discharge grilles, mass flows originated by pressure differences due to openings to surroundings, and air flow perturbation due to consumers’ passage nearby the frontal opening of the display cabinet, among others, affect the re-circulated air curtain behaviour and consequently the equipment’s overall thermal performance. This study presents a three-dimensional (3D) Computational Fluid Dynamics (CFD) modelling of the physical-mathematical phenomena occurring in an open refrigerated display cabinet, and particularly concerns the aerothermodynamics system of recirculated air curtain, under different magnitude values of the ambient air velocity (according to EN-ISO Standard 23953 and doubled one). A parametric study is undertaken for the air flow and heat transfer numerical predictions to determine the open refrigerated display cabinet’s thermal behaviour and of the re-circulated air curtain, taking into account the ambient air velocity’s magnitude. Results from experimental tests following EN-ISO Standard 23953 for climatic class n.er 3 (Tamb = 25 ºC, amb = 60%) are used to characterize the phenomena near inlets, outlets and physical borders. To prescribe boundary conditions as well as to validate numerical predictions of temperature and velocity distributions, the experimental results are applied.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.isbn978-989-96778-1-4
dc.identifier.urihttp://hdl.handle.net/10400.6/7586
dc.language.isoengpt_PT
dc.publisher5th European Conference on Computational Fluid Dynamics, ECCOMAS CFD 2010pt_PT
dc.subjectFluid Dynamicspt_PT
dc.subjectCD-ROMpt_PT
dc.subjectInstructionspt_PT
dc.subjectDeadlinespt_PT
dc.subjectConference sitept_PT
dc.titleCFD parametric study of ambient air velocity magnitude influence in thermal behaviour of open refrigerated display cabinetspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceLisboa, Portugalpt_PT
oaire.citation.title5th European Conference on Computational Fluid Dynamicspt_PT
person.familyNameGaspar
person.givenNamePedro Dinis
person.identifier.ciencia-id6111-9F05-2916
person.identifier.orcid0000-0003-1691-1709
person.identifier.ridN-3016-2013
person.identifier.scopus-author-id57419570900
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationb69e2ba0-43af-4cf7-873e-090fd9fc6c94
relation.isAuthorOfPublication.latestForDiscoveryb69e2ba0-43af-4cf7-873e-090fd9fc6c94

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ECCOMAS_CFD2010_1021_vf.pdf
Size:
278.13 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: