Repository logo
 
Publication

Experimental study of the interference in air curtains due to the parallel transfer in front of refrigerated display cases

dc.contributor.authorNascimento, Samuel Mariano do
dc.contributor.authorHeidinger, Gustavo Galdi
dc.contributor.authorGaspar, Pedro Dinis
dc.contributor.authorSilva, Pedro Dinho da
dc.date.accessioned2019-10-23T10:33:50Z
dc.date.available2019-10-23T10:33:50Z
dc.date.issued2014-06
dc.description.abstractRefrigerated display cases used to expose perishable food for sale in convenience stores and supermarkets are subject to human interference. Clients and repositories transit in front of display cases and frequently remove or place food products on the shelves depending on sales volume. This movement is part of the trade, although it has consequences on the display case performance. Each interference drags or breaks the air curtain resulting in the modification of air flow and promoting the ambient air thermal entrainment that consequently change the equipment's working conditions and increase 2% to 5% its energy consumption. This experimental study quantifies the air temperature increase and the energy consumption increase when there is an interference drag due to people inside the store passing parallel to the frontal opening of the display case. The tests were performed using a robotic mannequin that systematically transfers around the display case (5 minutes lap during 24 hours) and parallel to the frontal opening of the refrigerated display case with a translation velocity of 0.6 m/s. The results show that the products temperature increases 16% and the energy consumption increases 4.6% due to the air movement generated by the robotic mannequin transfer. These results are part of a more complex evaluation of the air curtain interference by humans to be used in the development of new products on an industrial scale.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.urihttp://hdl.handle.net/10400.6/7342
dc.language.isoengpt_PT
dc.publisherASME 2014 12th Biennial Conference on Engineering Systems Design and Analysis (ESDA2014)pt_PT
dc.subjectRefrigerated displaypt_PT
dc.titleExperimental study of the interference in air curtains due to the parallel transfer in front of refrigerated display casespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceCopenhagen, Denmarkpt_PT
oaire.citation.title12th Biennial Conference on Engineering Systems Design and Analysispt_PT
person.familyNameMariano do Nascimento
person.familyNameGaspar
person.familyNameSilva
person.givenNameSamuel
person.givenNamePedro Dinis
person.givenNamePedro
person.identifier.ciencia-id6111-9F05-2916
person.identifier.ciencia-id3C14-B985-13A1
person.identifier.orcid0000-0001-8232-9018
person.identifier.orcid0000-0003-1691-1709
person.identifier.orcid0000-0003-2204-3397
person.identifier.ridN-3016-2013
person.identifier.ridA-6638-2016
person.identifier.scopus-author-id57419570900
person.identifier.scopus-author-id7203088999
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication5ec9cd63-1bb7-4f59-8bb4-d9dc0e801cc5
relation.isAuthorOfPublicationb69e2ba0-43af-4cf7-873e-090fd9fc6c94
relation.isAuthorOfPublication483bd890-f402-4ce4-b740-b37febcba37f
relation.isAuthorOfPublication.latestForDiscovery483bd890-f402-4ce4-b740-b37febcba37f

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ESDA2014-20487.pdf
Size:
730.56 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: