Desenvolvimento e validação de um método analítico para determinação do repelente IR3535

datacite.subject.fosCiências Naturais::Ciências Químicas
dc.contributor.advisorAlba, Maria Eugénia Gallardo
dc.contributor.advisorPires, Bruno Miguel Pinheiro
dc.contributor.advisorRodilla, Jesus Miguel Lopez
dc.contributor.authorConceição, Elizandra Joselita Lende da
dc.date.accessioned2025-11-26T14:38:41Z
dc.date.available2025-11-26T14:38:41Z
dc.date.issued2025-03-24
dc.date.submitted2025-01-29
dc.description.abstractAs doenças transmitidas por mosquitos estão entre as mais mortais, tornando estes insetos uma ameaça significativa à saúde global. Nesse contexto, a tecnologia associada aos repelentes de insetos desempenha um papel crucial no controlo eficaz e sustentável destas pragas. Entre as alternativas disponíveis, o repelente éster etílico do ácido 3- (Nbutil-N-acetil)aminopropiônico (IR3535) destaca-se pela sua eficácia, segurança, baixa irritação cutânea e menor toxicidade em comparação com outros repelentes. O presente estudo teve como objetivo desenvolver e validar um método analítico para quantificar a concentração da substância ativa, IR3535, presente em formulações de repelentes. Para tal, utilizou-se a cromatografia líquida de alta eficiência acoplada a um detetor de diode array (HPLC-DAD). Numa primeira fase, realizaram-se extrações em amostras têxteis fortificadas com IR3535, utilizando diferentes solventes: acetonitrilo, metanol, acetato de etilo e hexano. O objetivo foi identificar o solvente com maior eficiência na extração. A análise estatística revelou que, apesar das variações nos solventes utilizados, não houve diferenças estatisticamente significativas nas áreas obtidas, indicando que todos os solventes testados apresentaram eficácia semelhante na extração. Seguidamente, procedeu-se à validação do método de acordo com as diretrizes da Food and Drug Administration, avaliando parâmetros como linearidade, limites analíticos (deteção e quantificação), precisão e exatidão. A análise do coeficiente de correlação da curva de calibração para os padrões de IR3535 demonstrou uma forte correlação entre as absorvâncias e as concentrações dos padrões, com um coeficiente de determinação (R² = 1). O limite inferior de quantificação foi de 1,9 µg/mL. O método desenvolvido foi aplicado com sucesso para a identificação e quantificação de IR3535 em amostras provenientes das indústrias têxtil e química.por
dc.description.abstractMosquito-borne diseases are among the deadliest, making these insects a significant threat to global health. In this context, the technology associated with insect repellents plays a crucial role in the effective and sustainable control of these pests. Among the alternatives available, the 3-(N-butyl-N-acetyl)aminopropionic acid ethyl ester repellent (IR3535) stands out for its efficacy, safety, low skin irritation and lower toxicity compared to other repellents. The aim of this study was to develop and validate an analytical method to quantify the concentration of the active substance, IR3535, present in repellent formulations. To this end, high-performance liquid chromatography coupled to a diode array detector (HPLCDAD) was used. Firstly, extractions were carried out on textile samples fortified with IR3535 using different solvents: acetonitrile, methanol, ethyl acetate and hexane. The aim was to identify the solvent with the highest extraction efficiency. Statistical analysis revealed that, despite the variations in the solvents used, there were no statistically significant differences in the areas obtained, indicating that all the solvents tested showed similar extraction efficiency. The method was then validated in accordance with Food and Drug Administration guidelines, assessing parameters such as linearity, analytical limits (detection and quantification), precision and accuracy. Analysing the correlation coefficient of the calibration curve for the IR3535 standards showed a strong correlation between the absorbances and the concentrations of the standards, with a determination coefficient (R² = 1). The lower limit of quantification was 1.9 µg/mL. The developed method was successfully applied for the identification and quantification of IR3535 in samples from the textile and chemical industries.eng
dc.identifier.tid204047790
dc.identifier.urihttp://hdl.handle.net/10400.6/19397
dc.language.isoporpor
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectCromatografia Líquida de Alta Resolução Acoplada a UM Detetor de Diode Arraypor
dc.subjectHplc-Dadpor
dc.subjectIr3535por
dc.subjectRepelentespor
dc.subjectValidaçãopor
dc.titleDesenvolvimento e validação de um método analítico para determinação do repelente IR3535por
dc.typemaster thesispor
dspace.entity.typePublication
thesis.degree.name2º Ciclo em Química Industrialpor