Repository logo
 
Loading...
Profile Picture
Person

Simões, Rogério Manuel Santos

Search Results

Now showing 1 - 3 of 3
  • Toxicity reduction and biodegradability enhancement of cork processing wastewaters by ozonation
    Publication . Gomes, A.C.; Silva, Lúcia; Simões, Rogério; Canto, N.; Albuquerque, Antonio
    Biodegradability enhancement and detoxification of cork boiling wastewater (CBW) are required for the successful implementation of biological treatment options. We studied the possibility of achieving these goals through ozonation pre-treatment by experimenting on the effect of ozone dose and pH. The CBW used had a pH of 5.81, a chemical oxygen demand (COD) of 1,865 mg L-1, a biochemical oxygen demand (BOD5) of 498 mg L-1 and total phenol (TP) and tannin compounds concentrations of 523 and 399 mg L-1, respectively. The ozone doses ranged from 0.27 to 2.63 for the O-3(applied)/COD0 ratios with samples at natural pH and set to 3.33 and 9.96. Ozonation allowed the BOD20/COD ratio (biodegradability index) to increase from 0.37 to 0.63 and a toxicity reduction from 3.08 to 1.24 TU (Microtox). The corresponding removals obtained were 15.2-62.0%, 38.4-83.2% and 56.7-92.1% for COD, TP and colour, respectively. The best outcome of ozonation pre-treatment requires O-3(applied)/COD0 ratios over 1.5 and an acid pH. The increase of TP removals with ozone dose at acid pH led to biodegradability enhancement and CBW detoxification. However, for similar conditions the highest COD removals were obtained at alkaline pH due to the hydroxyl radicals' high oxidation ability but lack of selectivity.
  • Biodegradability enhancement and detoxification of cork processing wastewater molecular size fractions by ozone
    Publication . Santos, Diana C.; Silva, Lúcia; Albuquerque, Antonio; Simões, Rogério; Gomes, A.C.
    Cork boiling wastewater pollutants were fractionated by sequential use of four ultrafiltration membranes and five fractions were obtained: four retentates (>100, 50-100, 20-50 and 10-20 kDa) and one permeate (<10 kDa); which were used to study the correlation of molecular size with biodegradability and toxicity before and after ozonation. The results show that molecular size is correlated with organic load and restrains biodegradability. The fraction with >100 kDa corresponds to 56% of the organic load and the one with <10 kDa only 8%. The biodegradability of fractions increased 182% with fractions molecular size reduction from >100 to < 10 kDa and the chemical oxygen demand (COD) was from 3436 to 386 mg L-1. For biodegradability enhancement the best outcome of ozonation was obtained with compounds having molecular size >20 kDa and range from 5% up to 175% for applied ozone doses to COD ratios between 0.15 and 0.38.
  • Cork Boiling Wastewater Treatment in Pilot Constructed Wetlands
    Publication . Gomes, A.C.; Stefanakis, Alexandros; Albuquerque, António; Simões, Rogério
    most studies published on the topic of cork boiling wastewater (CBW) treatment or valorization used physico-chemical treatment options rather than biological processes. However, the related costs are high and above those of the biological treatment alternative for wastewaters with similar organic loads but from different sources. Thus, con- structed wetland systems (CWs) can be an alternative to conventional biological treatment systems, namely to activated sludge systems, with the prominent virtues of low construction and operation costs. Until today, there is no study or research published for the treatment of CBW using CW systems. Thus, this investigation is a novelty and included the monitoring over a period of four years of the operation of a horizontal subsurface flow constructed wetland (HSF CW) microcosm-scale system planted with common reeds (Phragmites australis) and filled with light expanded clay aggregates (LECA), as support media for the plants and for biofilm development. The contribution of plants to the treatment was assessed by the comparison with an identical wetland unit without plantation (control bed). After this extended period of operation intended to maximize biomass development and acclimatization, which included stepwise increase of the organic load rate (OLR) up to 8.9 g COD/m2/d, the assessment of the treatment capacity of the system was done by doubling the OLR to 16.4 g COD/m2/d during 200 days.