- Estudo numérico do desempenho térmico de um armário exterior para equipamentos de telecomunicações móveisPublication . Duarte, Miguel Vicente; Silva, Pedro Dinho da; Pires, Luís Carlos Carvalho; Gaspar, Pedro DinisOutdoor cabinets that house telecommunication equipment are used to protect electronic equipment from the harsh environmental conditions. The number of outdoor cabinets used has been growing in recent decades, boosted by the world expansion of mobile telecommunications networks. The disposition of telecommunications equipment inside a cabinet (i.e., the thermal design) became a critical factor due to the miniaturization of electronic components and the increase of packing density. To mitigate this problem, energy-intensive cooling techniques (e.g., air conditioning) began to be used. Studies shown that approximately 25% of the total energy consumed in an outdoor cabinet is used for cooling. It is intended with this work, the thermal study of an outdoor cabinet using a CFD software to characterize its thermal behaviour, according to the influence of the environment temperature, the air flow through the cabinet and the heat dissipated in its interior by the telecommunications equipment. According the results obtained in this study it can be concluded that even for the less favourable case (TA=20.1 °C; Qar=60 m3 h -1 e qdis=480 W), none of the telecommunications equipment inside the cabinet is under risk, since the Tmax,cabinet ≈ 4 0°C is lower than the Tmax,recommended ≈55°C.
- Experimental comparison between R409A and R437A performance in a heat pump unitPublication . Duarte, Miguel Vicente; Pires, Luís Carlos Carvalho; Silva, Pedro Dinho da; Gaspar, Pedro DinisThis paper reports an experimental comparison between the use of the refrigerants R409A and R437A in a heat pump unit designed and developed to work with R12. Although the use of both refrigerants in new equipments were abolished in EU and US according the new F-Gas Regulation of EU and SNAP, they still being used as options for R12 in old equipments, especially in developing countries. Both refrigerants were studied for the same test conditions, according to two groups of tests: group A (variation of the heat source temperature) and group B (variation of refrigerant flow rate). The results obtained showed that the R437A presents a higher discharge pressure and a lower discharge temperature. The heating and cooling capacities of both refrigerants were similar, as well as the exergetic efficiency. For the group A of tests the COP of both refrigerants was similar and for the group B of tests the R409A presented an average COP 15% higher. According to the results obtained it is recommended the use of R409A in old equipments (as transition refrigerant) until the acquisition of equipments operating with refrigerants with low-GWP becomes technically and economic feasible.
- Estudo de bomba de calor: fluidos de trabalho e eficiência energéticaPublication . Duarte, Miguel Vicente; Pires, Luís Carlos Carvalho; Gonçalves, Luís Carlos CarrilhoTem-se verificado nos últimos anos um aumento das preocupações relacionadas com as consequências do efeito antropogénico no ambiente. Como consequência dessa relação tem resultado, por exemplo, o aumento da temperatura média global à face do Planeta Terra. A utilização de equipamentos de refrigeração por compressão de vapor, nas suas múltiplas aplicações, tem dado um importante contributo no referido impacto no ambiente. Efectivamente, os fluidos refrigerantes empregues nesses sistemas apresentam características que os tornam nocivos para o ambiente. Em particular, contribuem para a destruição da camada de ozono e para o aumento do efeito de estufa. Com o objectivo de mitigar esses efeitos existe legislação que regula a utilização dos fluidos refrigerantes e promove a sua substituição por outros mais amigos do ambiente. No presente trabalho é abordada a substituição de um fluido refrigerante do tipo HCFC, R-409A, por outro mais recente do tipo HFC, R-437A. O trabalho incluiu um estudo experimental realizado numa unidade de refrigeração por compressão de vapor que foi testada com ambos os fluidos. Foram realizados ensaios para uma diversificada gama de condições. O estudo teve como principal propósito avaliar o comportamento de cada um dos dois fluidos, por forma a perceber a relevância da substituição. Concluiu-se que os fluídos apresentam, para as condições estudadas, desempenhos energéticos e exergéticos idênticos, pelo que se assume como aconselhável a referida substituição.