Publication
Monitorização da temperatura do solo
datacite.subject.fos | Engenharia e Tecnologia::Engenharia Eletromecânica | por |
dc.contributor.advisor | Pires, Luis Carlos Carvalho | |
dc.contributor.advisor | Gomes, LuĆs Manuel Ferreira | |
dc.contributor.author | Calado, Anthony | |
dc.date.accessioned | 2019-12-12T16:30:07Z | |
dc.date.available | 2019-12-12T16:30:07Z | |
dc.date.issued | 2016-11-11 | |
dc.date.submitted | 2016-10-10 | |
dc.description.abstract | O aproveitamento da energia geotĆ©rmica de muito baixa entalpia mediante a utilização de tubos enterrados no solo tem sido visto como uma estratĆ©gia capaz de contribuir para a poupanƧa de energia no setor dos edifĆcios. No presente trabalho Ć© proposto um permutador de calor ar-solo, de formato inovador e compacto, como estratĆ©gia de arrefecimento. Adicionalmente, Ć© proposta a monitorização da temperatura do solo em trĆŖs localizaƧƵes diferentes, todas na cidade da CovilhĆ£. Assim, o trabalho agora apresentado incluiu o desenvolvimento, a construção e a implementação, quer do permutador de calor, quer das sondas de temperatura, e a realização de estudos experimentais em ambos. De forma sucinta, o permutador apresenta um circuito de tubagem em formato helicoidal quadrangular, em PVC, que possui uma entrada e uma saĆda de ar Ć superfĆcie e em que a circulação de ar nos tubos Ć© efetuada com recurso a um, ou dois, ventiladores hĆ©lico-centrĆfugos aplicados nas respetivas bocas de admissĆ£o e extração de ar. Relativamente Ć s sondas, estas envolvem cinco pontos de medida, os quais permitem a monitorização da temperatura do solo, metro a metro, atĆ© os 5 metros de profundidade. Após a construção destes elementos, foram implementados nas localizaƧƵes estabelecidas, em que, posteriormente, foram submetidos a um conjunto de estudos experimentais que visaram, por um lado, conhecer o desempenho tĆ©rmico e energĆ©tico do permutador na estação de arrefecimento (verĆ£o) e, por outro, analisar o padrĆ£o apresentado pela temperatura do solo nas trĆŖs localizaƧƵes seleccionadas. Os resultados do estudo relativo ao permutador revelam que este possui potencialidades para o arrefecimento de edifĆcios. Os dados obtidos da monitorização da temperatura do solo, mostram temperaturas adequadas, quer para o arrefecimento, quer para aquecimento do ar interior de edifĆcios. | |
dc.description.abstract | The use of geothermal energy of very low enthalpy through the use of pipes buried in the ground, has been seen as a strategy to contribute to energy conservation in the sector of buildings. In this paper it is proposed an air-ground heat exchanger, with innovative and compact design, as cooling strategy. In addition, it is proposed to monitor the soil temperature at three different locations, all in the city of Covilhã. Thus, the work now presented includes the development, construction and implementation of both the heat exchanger and the temperature sensors, and the realization of experimental studies on both. Briefly, the heat exchanger has a helical quadrangular pipe circuit, made of PVC, having an inlet and an air outlet at the ground surface, which air circulation in the tubes is effected using one or two helical-centrifugal fans, applied in the respective mouths of intake and extraction of the air. Regarding the probes, these involve five measurement points, which allow monitoring of soil temperature, meter by meter, up to 5 meters deep. After construction, these elements were implemented in the set locations, which subsequently underwent a series of experimental studies aimed to meet the thermal and energy performance of the heat exchanger in the cooling season (summer) and, analyze the pattern shown by soil temperatures in the three selected locations. The results of the studies show that the heat exchanger has the potential for the cooling of buildings. The data obtained by the temperature monitoring of the soil, show suitable temperatures for cooling and heating the indoor air of buildings. | |
dc.identifier.tid | 202331350 | |
dc.identifier.uri | http://hdl.handle.net/10400.6/7782 | |
dc.language.iso | por | por |
dc.subject | Arrefecimento e Aquecimento Pelo Solo | por |
dc.subject | Energia GeotƩrmica | por |
dc.subject | Energia GeotƩrmica de Muito Baixa Entalpia | por |
dc.subject | Permutador de Calor Ar-Solo | por |
dc.title | Monitorização da temperatura do solo | por |
dc.title.alternative | Desenvolvimento e estudo experimental de um permutador de calor ar-solo | por |
dc.type | master thesis | |
dspace.entity.type | Publication | |
rcaap.rights | openAccess | por |
rcaap.type | masterThesis | por |
thesis.degree.name | 2º Ciclo em Engenharia Eletromecânica | por |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- 5181_10103.pdf
- Size:
- 6.17 MB
- Format:
- Adobe Portable Document Format