Publication
Determinação de antidepressivos em plasma e urina
| dc.contributor.advisor | Alba, Maria EugƩnia Gallardo | |
| dc.contributor.author | Domingos, Ana Sofia Marques | |
| dc.date.accessioned | 2014-06-03T18:00:22Z | |
| dc.date.available | 2014-06-03T18:00:22Z | |
| dc.date.issued | 2009 | |
| dc.description.abstract | Os casos de depressĆ£o tĆŖm vindo a aumentar cada vez mais. Muitas vezes por falta de diagnóstico atempado o tratamento inicial nĆ£o Ć© eficaz, o que faz com que o nĆŗmero de doentes crónicos continue a aumentar, aumentando consequentemente o consumo deste tipo de medicamentos. Em Portugal, os dados publicados pela Autoridade Nacional do Medicamento e Produtos de SaĆŗde I.P. (INFARMED) referem que o subgrupo farmacoterapĆŖutico antidepressivos e psicotrópicos estava, em 2000, entre os 10 primeiros no que diz respeito aos encargos para o ServiƧo Nacional de SaĆŗde. A prescrição dos antidepressivos de nova geração, como os inibidores selectivos da recaptação da serotonina, tem sido crescente nos Ćŗltimos anos, jĆ” que apresentam menos toxicidade para o organismo e um menor nĆŗmero de efeitos secundĆ”rios. No entanto, nem sempre esta medicação Ć© eficaz, continuando assim a prescrever-se antidepressivos tricĆclicos e inibidores da monoaminoxidase, que apresentam uma elevada toxicidade e sĆ£o muitas vezes usados em actos suicidas. O objectivo a que nos propusemos com este trabalho foi desenvolver e comparar vĆ”rias tĆ©cnicas para a preparação de amostras, como a extracção lĆquido-lĆquido (LLE) e a extracção em fase sólida (SPE), usando diferentes solventes e tipos de enchimento para a detecção de antidepressivos em plasma e urina. Os extractos foram analisados por cromatografia lĆquida de alta eficiĆŖncia (HPLC) acoplada a um detector de fotodiodos (PDA). Foram estudados nove antidepressivos: amitriptilina, nortriptilina, clomipramina, dotiepina, mianserina, trazodona, fluoxetina, sertralina e protriptilina, tendo sido este Ćŗltimo usado como padrĆ£o interno.Os parĆ¢metros estudados foram a selectividade, recuperação e limites de detecção, tendo estes parĆ¢metros sido avaliados de acordo com as normas internacionalmente aceites para a validação de mĆ©todos bioanalĆticos. Os valores de recuperação obtidos situaram-se entre 16-82% para a LLE e 42-97% para a SPE. De um modo geral, as tĆ©cnicas de SPE utilizadas demonstraram ser mais adequadas para a determinação deste tipo de compostos em fluidos biológicos, devido Ć presenƧa de um nĆŗmero menor de interferĆŖncias endógenas. Por outro lado, a simplicidade de execução desta tĆ©cnica torna-a mais facilmente automatizĆ”vel. Finalmente, foi ainda possĆvel demonstrar que o tipo de equipamento analĆtico utilizado no decorrer deste trabalho (HPLC/PDA) Ć© uma tĆ©cnica Ćŗtil e ao alcance de qualquer laboratório para uma primeira fase da optimização de processos extractivos, reservando-se tĆ©cnicas mais dispendiosas [como por exemplo LC/MS (MS) ou UPLC/MS (MS)] para a posterior validação dos mĆ©todos analĆticos desenvolvidos. | por |
| dc.description.abstract | Depression situations are increasing every year. Initial treatment measures are often non-effective, and this can be due to the lack of an early diagnosis, leading to an increase in the number of patients with chronic disease. As a consequence, the consumption of antidepressant drugs also increases. In Portugal, and according to the published data by Autoridade Nacional do Medicamento e Produtos de SaĆŗde I.P. (INFARMED) referring to the year 2000, antidepressant and psychotropic medicines were included in the top 10 of the most burdensome therapeutic groups to the public treasury. The prescription of new generation antidepressants, such as the selective inhibitors of serotonin reuptake, has increased in recent years, as these are less toxic and present fewer side effects. However, this class of drugs is not always effective, thus tricyclic antidepressants and is monoaminoxidase inhibitors are still being largely prescribed; the toxicity of these drugs is high, and they are often used in suicides. The objective of this work was the development and comparison of several techniques for sample preparation, such as liquid-liquid extraction (LLE) or solid-phase extraction (SPE), for the detection of nine selected antidepressants in plasma and urine. Several different solvents and SPE cartridges (and sorbents) have been used, and extracts were analysed by high performance liquid chromatography (HPLC) coupled to a photodiode array detector (PDA). We have studied nine antidepressants, and these were amitriptyline, nortryptiline, clomipramine, dothiepin, mianserine, trazodone, fluoxetine, sertraline and protriptyline (internal standard). The studied parameters included selectivity, absolute recovery and detection limits, and these were evaluated taking into account internationally accepted criteria for bioanalytical method validation. The obtained recovery values were between 16-82% for LLE and 42-97% for SPE. In general, SPE-based techniques have shown more suitability for the determination of such compounds in these biological fluids due to the presence of less endogenous interferences. Moreover, this technique is more easily automated. Finally, it was further possible to demonstrate that the instrumentation used in this study (HPLC/PDA) is an useful and accessible analytical tool to any laboratory for the first stage of optimization of extraction methods, reserving more expensive techniques [e.g. LC/MS (MS) or UPLC/MS (MS)] for the subsequent validation of the developed analytical methods. | |
| dc.identifier.uri | http://hdl.handle.net/10400.6/1764 | |
| dc.language.iso | por | por |
| dc.publisher | Universidade da Beira Interior | por |
| dc.subject | Serotonina | por |
| dc.subject | Noradrenalina | por |
| dc.subject | Antidepressivos tricĆclicos | por |
| dc.title | Determinação de antidepressivos em plasma e urina | por |
| dc.type | master thesis | |
| dspace.entity.type | Publication | |
| oaire.citation.conferencePlace | Covilhã | por |
| rcaap.rights | openAccess | por |
| rcaap.type | masterThesis | por |
