Repository logo
 
Publication

Estudo comparativo entre as avaliações subjetivas e objetivas da refração ocular

datacite.subject.fosCiências Médicas::Ciências da Saúde::Ciências da Visãopor
dc.contributor.advisorFiadeiro, Paulo Torrão
dc.contributor.advisorMonteiro, Pedro Miguel Lourenço
dc.contributor.authorPina, Pedro Miguel dos Anjos
dc.date.accessioned2018-11-05T14:37:42Z
dc.date.available2018-11-05T14:37:42Z
dc.date.issued2016-11-10
dc.date.submitted2016-9-19
dc.description.abstractEste trabalho foi realizado com o intuito de desenvolver um estudo comparativo entre a refração objetiva com a refração subjetiva. Para tal utilizou- se o autorefratómetro Nidek 310A e o autorefratómetro Unicos URK-800. A refração subjetiva foi efetuada monocularmente através de testes optométricos convencionais e as medições objetivas foram feitas através dos autorefratómetros já referidos. Participaram no estudo 107 sujeitos, sendo excluídos os sujeitos com quaisquer patologias oculares, historial de cirurgias ou qualquer trauma que afetasse a visão, e acuidade visual inferior a unidade. Na análise estatística os valores da refração são transformados em componentes vetoriais segundo a decomposição de Fourier. Com análise gráfica de Bland-Altman, comparam-se os valores da refração subjetiva com a refração objetiva e as diferenças entre os dois autorefratómetro. Para complementar análise dos dados, as componentes vectorias são convertidas para a forma convencional esférica-cilíndrica. Os resultados obtidos mostram uma maior exatidão dos dois aparelhos na parte cilíndrica, sendo o autorefratómetro Nidek AR-310A, mais fiável que o Únicos URK-800, embora as diferenças entre os dois autorefratómetros não fosse clinicamente significativa.por
dc.description.abstractThis dissertation was written aiming the development of a comparative study between objective and subjective refraction. To fulfil this objective an auto refractometer Nidek AR-310A and an auto refractometer Unicos URK-800 were used. Subjective refraction was performed monocularly through conventional optometric tests, while objective refraction was performed through the previously mentioned auto refractometers. 107 subjects participated in the study, excluding any cases of subjects with ocular diseases, surgical history or any trauma that would affect vision, and visual acuity lower than 20/20. For statistical analysis purposes, refractive results were transformed in vectorial components, accordingly to Fourier decomposition. Resorting to Bland-Altman graphical analysis, objective and subjective refraction were compared and also the differences between the two instruments. Result show a greater accuracy in the two instruments at the cylindrical component level, with auto refractometer Nidek AR-310A yielding better results, although the two instruments do not display clinical significant differences.eng
dc.identifier.tid201774739
dc.identifier.urihttp://hdl.handle.net/10400.6/6285
dc.language.isoporpor
dc.subjectpor
dc.subjectAnálise Gráfica de Bland-Altmanpor
dc.subjectAutorefratómetro Nidek Ar-310apor
dc.subjectAutorefratómetro Unicos Urk-800por
dc.subjectRefração Objetivapor
dc.subjectRefração Subjetivapor
dc.titleEstudo comparativo entre as avaliações subjetivas e objetivas da refração ocularpor
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspor
rcaap.typemasterThesispor
thesis.degree.name2º Ciclo em Optometria Em Ciências da Visãopor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
4998_9859.pdf
Size:
1.68 MB
Format:
Adobe Portable Document Format